The Annoying Problem of Multiple Grounds (T-Spice) without a Clue Where to Look


What's happening - T-Spice refuses to run because of what it "found". Except, it doesn't tell *you* where to find it.

In my case, the block had GND as a pin and, because of using the SPICE_sources/vbus8bits, (inside which, voltage-sources are connected to Gnd (the global Ground)), the netlister added another Gnd pin to the pin list of the subckt.

Then, GND and Gnd are the same because T-Spice is case-insensitive - that's what they said.

So, all you need to do is ensure you don't use voltage sources in your "sim" view of a cell that are tied to Gnd. Use the local ground and you'll be fine